Abstract
Abstract This experimental study aimed to investigate the effect of a newly shaped condenser on the thermal performance and operational parameters of a horizontally rotating wickless heat pipe. The new condenser shape has been developed based on assessing the effect of conical external ends and inner tapered wall condensers. The newly developed condenser configuration implies an external conical end of 60° and an inner tapered walls condenser of 3°. The heat pipe was subjected to a consistent rotational speed of 1500 rpm while being exposed to different heat loads, ranging from 25 to 200 W. Various filling ratios of water, from 5 to 55% of the total inner volume of the heat pipe, have been tested at rotation speeds of 750, 1000, and 1500 rpm. The results indicated that the heat pipe with the advanced condenser has a superior performance over the ones with the plain condenser by 46.75%, the conical end condenser by about 31.15%, and the tapered condenser by about 7.54%, on average over the tested heat loads from 25 to 200W. The filling ratio of 25% achieved better performance than the other tested filling ratios as the effective thermal resistance of the heat pipe decreased by 3.1 to 10.1%, 2.8 to 19.5%, and 8.9 to 24.8% for rotational speeds 750, 1000, and 1500 rpm, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Thermal Science and Engineering Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.