Abstract

To study the effect of rotation errors on the γ pass rate of volume-modulated arc therapy (VMAT) plan in rectal cancer based on the ArcCheck phantom. CT data from 20 rectal cancer patients underwent VMRT were selected randomly for this study. Targeting areas were selected, and clinical radiotherapy and validation plans were formulated. ArcCheck model was selected to validate the radiotherapy plans. The effect of the rotation errors on the dosimetric verification for VMAT in rectal cancer was simulated and analyzed with ArcCheck model software. When there was no rotation errors, the γ pass rate of VMRT plans was more than 95%. When the absolute rotation angle was less than or equal to 1°, the γ pass rate of VMAT plans was more than 90%, meeting the clinical requirements. When the absolute rotation angle was greater than 1°, the γ pass rate was less than 90%, which did not meet clinical requirements. The rotation errors affect the γ pass rate of VMAT plans. The larger the rotation angle, the lower the γ pass rate. It meets clinical requirements when the rotation error is less than or equal to 1°.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.