Abstract

Quantification of the loss generation of ducted contra-rotating fan (CRF) blades is difficult to achieve, since there are no guide vanes between rotors. A blade design program was established to investigate the relationship between radial velocity distribution and incurred loss. Numerical and experimental techniques were used to confirm the optimal configuration's overall performance. The relationship between loss and velocity distribution under the impact of spanwise load distribution was confirmed by the entropy contour from various perspectives. The appropriate radial velocity distribution can improve the operating efficiency of a CRF by reducing the entropy around the annulus under design and near-stall conditions. This regularity could provide some strategies in the design of contra-rotating blades.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call