Abstract
The paper presents issues concerning the calculation of fatigue life under programmable load. Aim of this study is to analyze the sensitivity of the calculation method based on the variation of the exponent m used in the description of Wöhler fatigue chart. Arbitrary adoption of the recommendations contained in the FITNET procedures in fatigue module (the path 2b for normal stress) for the value of the exponent m = 5 can lead to significant differences in the calculation of fatigue life. This is due to the fact that the value of the exponent m obtained by experimental test of constructional steels and alloy is in within wide limits of variation from 3 to 30 with mean value in excess of 5. Based on the results of the fatigue life calculations for steel C45 and X5CrNi18-10 (1.4301) is noticeable a significant impact of exponent m on the fatigue life. This effect depends on the strain value in the load spectrum and increases with the increase of the maximum amplitude of stresses in the program Sa max.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.