Abstract
The paper discusses the bond strength between a high-performance concrete (HPC having a 28-day strength of 95 MPa) and reinforcing bars. This was measured in a series of beam tests in which the concrete type (HPC and ordinary concrete), reinforcement diameter (between 10 and 25 mm), and reinforcement surface condition (smooth and deformed bars) were varied. In general, concrete-reinforcement bond strength increases with the tensile strength of the concrete, and at a hgher rate with smaller reinforcement (a more marked scale effect).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.