Abstract
A high-temperature ultrasonic fatigue testing system was developed to evaluate the gigacycle fatigue properties of Ti-17. Ultrasonic (20 kHz) fatigue tests were performed at room temperature, 200°C and 350°C, respectively. The dynamic Young’s modulus and fatigue endurance limit decrease with increasing temperature linearly. Rotating bending (50 Hz) tests were performed to evaluate the influence of loading frequency at room temperature, 200°C and 350°C, respectively. There is an obviously loading frequency effect at elevated temperature, although no loading frequency effect at room temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Key Engineering Materials
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.