Abstract

Prior studies have evidenced the potential for enhancing boiling heat transfer through modifications of surface or fluid properties. The deployment of nanofluids in pool boiling systems is challenging due to the deposition of nanoparticles on structured surfaces, which may result in performance deterioration. This study addresses the use of TiO2–water nanofluids (mass concentrations of 0.001 wt.% and 0.1 wt.%) in pool boiling heat transfer and concurrent mitigation of nanoparticle deposition on superhydrophobic laser-textured copper surfaces. Samples, modified through nanosecond laser texturing, were subjected to boiling in an as-prepared superhydrophilic (SHPI) state and in a superhydrophobic state (SHPO) following hydrophobization with a self-assembled monolayer of fluorinated silane. The boiling performance assessment involved five consecutive boiling curve runs under saturated conditions at atmospheric pressure. Results on superhydrophilic surfaces reveal that the use of nanofluids always led to a deterioration of the heat transfer coefficient (up to 90%) compared to pure water due to high nanoparticle deposition. The latter was largely mitigated on superhydrophobic surfaces, yet their performance was still inferior to that of the same surface in water. On the other hand, CHF values of 1209 kW m−2 and 1462 kW m−2 were recorded at 0.1 wt.% concentration on both superhydrophobic and superhydrophilic surfaces, respectively, representing a slight enhancement of 16% and 27% compared to the results obtained on their counterparts investigated in water.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call