Abstract

The effect of surface preparation on electroless Ni‐P plating on carbon fiber reinforced cyanate ester resin laminate has been investigated. Three different surface chemical etching ways were performed, namely: (i) hexanediamine etching, (ii) hexanediamine followed by aniline etching, and (iii) aniline etching. The results indicated that Ni‐P coating on hexanediamine etching or hexanediamine followed by aniline etching pretreated carbon fiber reinforced cyanate ester resin laminates usually tended to be cracked, veined, and low adhesion, while aniline etched laminates showed a homogenous roughing surface which is suitable for subsequently uniform, cellular, and good adhesion Ni‐P plating. POLYM. COMPOS., 37:1161–1166, 2016. © 2014 Society of Plastics Engineers