Abstract

The ohmic contact interface between diamond and metal is essential for the application of diamond detectors. Surface modification can significantly affect the contact performance and eliminate the interface polarization effect. However, the radiation stability of a diamond detector is also sensitive to surface modification. In this work, the influence of surface modification technology on a diamond ohmic contact under high-energy radiation was investigated. Before radiation, the specific contact resistivities (ρ c) between Ti/Pt/Au-hydrogen-terminated diamond (H-diamond) and Ti/Pt/Au-oxygen-terminated diamond (O-diamond) were 2.0 × 10−4 Ω⋅cm2 and 4.3 × 10−3 Ω⋅cm2, respectively. After 10 MeV electron radiation, the ρ c of Ti/Pt/Au H-diamond and Ti/Pt/Au O-diamond were 5.3 × 10−3 Ω⋅cm2 and 9.1 × 10−3 Ω⋅cm2, respectively. The rates of change of ρ c of H-diamond and O-diamond after radiation were 2550% and 112%, respectively. The electron radiation promotes bond reconstruction of the diamond surface, resulting in an increase in ρ c.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.