Abstract

In order to clarify the effects of a great amount of static pre-strain (1/4 cycle) on fatigue life of AISI 316L stainless steel, strain controlled low cycle fatigue tests were carried out. Hardness and fracture ductility of specimens were measured. Results showed that in the case of a specimen with p=0.01, static pre-strain of 0.16 noticeably reduced a fatigue life. To clarify the reasons for the decrease in fatigue life with pre-strain, the maximum stress amplitude of the hysteresis loop was measured. In the case of the specimen with p=0.01, work softening was observed in the early stage of fatigue life. On the other hand, when the cyclic plastic strain ranges were p=0.10, no softening was observed. These results suggest that work softening is significant in determining the fatigue life of the specimens at a relatively low level of applied cyclic strain.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.