Abstract

Plasma transfer arc welding (PTAW) has been one of the popular methods for depositing thick hard facing. In this study, this method was used to lay the nickel hard-facing without tungsten carbide and with different compositions which are 35 wt%, 50 wt% and 60 wt% carbides. The hard facing was characterised using a scanning electron microscope with EDS and x-ray diffractometer (XRD). The corrosion behaviour was evaluated using three electrodes electrochemical test with saturated calmonel electrode (SCE) and platinum plate as the reference electrode and counter electrode respectively. The corrosion test shows that the hard facing had higher corrosion resistance in an alkaline environment compared to an acidic environment. The corrosion mechanism was by the dissolution of the nickel matrix, Ni3B dissolution is seen in an acidic environment while in alkaline electrolyte, the dendritic nickel dissolves preferentially.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.