Abstract

Statement of problemEvidence for the optimal spatial arrangement of magnetic attachments in implant-supported orbital prostheses is lacking. PurposeThe purpose of this in vitro study was to assess the effect of 6 different spatial arrangements on the retentive force of magnetic attachments following the in vitro simulation of clinical service by insertion-removal test cycles and the contribution of artificial aging to the morphological alterations induced on the magnetic surfaces. Material and methodsNi-Cu-Ni plated disk-shaped neodymium (Nd) magnetic units (d=5 mm, h=1.6 mm) were secured on leveled (50×50×5 mm, n=3) and angled (40×45×40 mm, interior angle=90 degrees, n=3) pairs of test panels in 6 different spatial arrangements: triangular_leveled (TL), triangular_angled (TA), square_leveled (SL), square_angled (SA), circular_leveled (CL), and circular_angled (CA) generating corresponding test assemblies (N=6). TL and TA arrangements included 3 magnetic units (3-magnet groups) and SL, SA, CL, and CA 4 (4-magnet groups). The retentive force (N) was measured at a mean crosshead speed of 10 mm/min (n=10). Each test assembly was subjected to insertion-removal test cycles with a 9-mm amplitude, ν=0.1 Hz, and n=10 consequent retentive force measurements at a crosshead speed of 10 mm/min at 540, 1080, 1620, and 2160 test cycles. Surface roughness alterations following the 2160 test cycles were measured by calculating the Sa, Sz, Sq, Sdr, Sc, and Sv parameters with an optical interferometric profiler with 5 new magnetic units used as a control group. Data were analyzed with 1-way ANOVA and Tukey HSD post hoc tests (α=.05). ResultsThe 4-magnet groups had statistically significantly higher retentive force than the 3-magnet ones at baseline and following the 2160 test cycles (P<.05). In the 4-magnet group, the ranking at baseline was SA<CA<CL<SL (P<.05) and following the test cycles SA=CA<CL<SL (P<.05). No statistically significant differences were found in the surface roughness parameters (Sa, Sz, Sq, Sdr, Sc, and Sv) following the 2160 test cycles among the experimental groups tested (P>.05). ConclusionsFour magnetic attachments placed on an SL spatial arrangement resulted in the highest retention force but presented with the highest force reduction following the in vitro simulation of clinical service by insertion-removal test cycles.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call