Laboratory measurements of the improvement of partition airborne-sound transmission loss in the presence of sound-absorptive partition facings are presented. For a double-leaf partition of 1/2-in.-thick gypsum board on 2×4-in. studs, the application of such facings has led to improvements in transmission loss in excess of 10 dB in the 1/3-octave bands above 1 kHz. Corresponding, but smaller, improvements have been measured at lower frequencies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.