Abstract

The most effective skin antiseptic solution to reduce the incidence of catheter-related bloodstream infections (CRBSI) remains unknown. To compare solutions with different chlorhexidine (CHG)-based concentrations and povidone-iodine (PVI) in adults with a central venous catheter (CVC) or arterial catheter, and identify an association with the incidence of CRBSI. This study evaluated randomized controlled trials comparing CHG and PVI antiseptic agents in patients aged ≥18 years with an underlying illness and a CVC or arterial catheter. The primary outcome was CRBSI rate. Network meta-analysis was performed by a frequentist-based approach with multi-variate random effects meta-analysis, and the effect size was expressed as relative risk (RR) with 95% confidence interval (CI). The search yielded 1511 records, of which five studies (2815 catheters) were included in the network meta-analysis. The risk of CRBSI was significantly lower with 1% CHG-alcohol than with 0.5% CHG-alcohol (RR 0.40, 95% CI 0.16-0.98; high certainty) or 10% PVI-aqueous (RR 0.31, 95% CI 0.15-0.63; high certainty). There was no significant difference in the risk of CRBSI between 1% CHG-alcohol and 2% CHG-aqueous (RR 0.35, 95% CI 0.12-1.04; moderate certainty) or other antiseptic solutions. The hierarchy of efficacy in reducing CRBSI was 1% CHG-alcohol, 0.5% CHG-alcohol, 2% CHG-aqueous and 10% PVI-aqueous. Antiseptic agents containing 1% CHG-alcohol were more strongly associated with reduced risk for CRBSI compared with agents containing 0.5% CHG-alcohol or 10% PVI-aqueous.