Abstract

AbstractSquare–form microfilters consisting of a two–layer porous membrane with nano–size pores and reinforced by silicon columns have been investigated. The change of layer thicknesses and reinforcement geometry modify the load–capacity of the device through the variation of strength properties. A simple thin plate model was constructed by substituting the effect of silicon columns by an equivalent third layer. Estimates for the load–capacity were made by finite element calculations. These estimates have been verified by experimental results. (© 2008 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.