Abstract
The objective of this research is to characterize the performance degradation attributable to the shutdown operations of polymer electrolyte fuel cells and to explore possible methods of reducing such degradation. As a result, it was made clear that a sequence of shutting off the air supply prior to stopping the hydrogen supply was effective in mitigating such performance degradation. Diagnostic technology revealed that the performance degradation was mainly observed at the cathode catalyst and that it was caused by so-called reversal current, which was triggered by air that crossed leak from the cathode to the anode.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.