Abstract
The effects of fluorine donor additives and initiation level on the HF laser output characteristics in a strong and short pulse initiation regime are experimentally and theoretically investigated. Typical parameters of the circular e beam used in the experiment are 2 MV, 60 kA, 65 ns FWHM, and 10 cm in diameter, and the e beam is injected longitudinally. The addition of SF6 gas to a mixture of F2/O2/H2 is found to increase not only the specific laser energy but also the electrical laser efficiency. The maximum laser energy obtained from the low-pressure mixture of F2/SF6/O2/H2=200/84/60/45 (Torr) is 4.4 kJ in a 70 ns FWHM with an electrical laser efficiency of 203% and a chemical laser efficiency of 18.6%. Based on the experimental results, the scaling of the HF laser was established in terms of specific HF laser energy and electrical laser efficiency.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.