Abstract

The performance of a reluctance synchronous machine in terms of torque and power factor depends on the two-axis inductances Ld and Lq of the machine. A finite element analysis method is used to determine these inductances for a reluctance machine with a normal cross-laminated rotor with two flux barriers per pole. By varying the rotor dimensions, the change in the difference and ratio of the inductances is examined. The effect of cross magnetisation on the two axis inductances is investigated by means of finite element analysis and measurements on an actual reluctance synchronous machine with a two flux barrier per pole rotor. The measured torque of the current-controlled reluctance machine drive is also given and compared with calculated results showing the effect of cross magnetisation. Hence, important conclusions are arrived at regarding the rotor design and cross magnetisation effect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.