Abstract

Background Bulk-fill resin composite has been introduced, their manufacturers claimed that they can be applied in bulks of 4mm, without necessitating a prolonged curing time, or a light curing unit with increased irradiance. Thus this study was conducted to evaluate the effect of resin thickness, and curing time on the micro-hardness of two bulk -fill resin composites; Tetric Evo-Ceram [TE], and X-trafil [XF]. Material and Methods 120 cylindrical specimens were prepared, and divided into 24 groups (n=5/group), representing the two bulk-fill resin composites, three different material thicknesses (2, 3 and 4 mm) and the four curing times used in the study (10, 20, 40, and 60 seconds). The specimens were light-cured from the top surface only. Specimens were stored in light proof containers in complete darkness at 37°C for 24 hours. Micro-hardness test was conducted on both top and bottom surfaces using Vickers micro-hardness tester with 500 g load and a dwell time of 15 seconds. Data were statistically analyzed by Four-way ANOVA of Variance. The significance level was set at P ≤ 0.05. Pearson Correlation used to determine significant correlations between mean micro-hardness (top) and (bottom) surfaces. Results Four way-ANOVA shows that different tested materials produce a statistically significant effect on mean micro-hardness (VHN) at p≤0.001, while thickness, curing time, and surface revealed statistically non significant effect on mean micro-hardness (VHN) at p≥0.05. [XF] (92.01±3.15 VHN) showed statistically significant higher mean micro-hardness than [TE] (54.13±4.96 VHN). Pearson Correlation revealed that there was a significant direct correlation between micro-hardness (bottom) and mean micro-hardness (top) (mm), r = 0.985, p (2-tailed) ≤0.001. Conclusions Within the limitations of this study, the bulk-fill resin composites used in this study can be placed and cured properly in the 4 mm bulk. Key words:Bulk-fill resin composite, micro-hardness, thickness, curing time.

Highlights

  • Resin composites are the widely used esthetic restorative materials

  • Mean and standard deviation (SD) for the micro-hardness (VHN) for the effect of different thickness and curing time tested within each group were presented in table 2

  • Except for TE, 4 mm bottom surface showed statistically significant lower mean micro-hardness compared to 2 and 3mm thickness bottom surfaces at p=0.03, when specimens cured for 60 seconds

Read more

Summary

Introduction

Resin composites are the widely used esthetic restorative materials. So manufactures have always to improve them in terms of the chemical composition and filler reinforcements. Dental composite restorations have a major drawback regarding the degree of cure, which is proportional to the amount of light they are exposed They polymerize to a certain depth which varies with the penetration of a light beam in the bulk material. This study investigated the effects of the resin thickness, and curing time on the micro-hardness of two of these bulk-fill resin composites. This study was conducted to evaluate the effect of resin thickness, and curing time on the micro-hardness of two bulk -fill resin composites; Tetric Evo-Ceram [TE], and X-trafil [XF]. Results: Four way-ANOVA shows that different tested materials produce a statistically significant effect on mean micro-hardness (VHN) at p≤0.001, while thickness, curing time, and surface revealed statistically non significant effect on mean micro-hardness (VHN) at p≥0.05. Conclusions: Within the limitations of this study, the bulk-fill resin composites used in this study can be placed and cured properly in the 4 mm bulk

Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.