Abstract

Calculations on the example of a steel column showed that with the combined effect of an explosion that causes deformation and subsequent fire, even without damaging the fire-retardant coat, there is a significant decrease in the fire resistance of the structure due to a decrease in the critical temperature. It is shown that, on the basis of the methodology proposed in this work, for hazardous operations industrial facilities, it is possible to predict the stability of steel columns in crash explosions followed by fire, as well as to recommend the values ​​of workloads and parameters of fire-retardant coats providing the necessary stability. It is also shown that when calculating the fire resistance limit of a steel structure with intumescent fire-retardant coat, it is necessary to take into account the proper heating time of steel structures until they lose strength.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.