Abstract

The external discharge plasma thruster removes the annular channel of the traditional Hall thruster, allowing the ionization region to appear outside the thruster, which is expected to reduce the plasma-wall interaction and extend the thruster lifetime. Due to its simpler structure and lighter weight, the external discharge plasma thruster is expected to be scaled down to lower power levels. In this work, the effect of radial scaling down on the performance of low-power external discharge plasma thrusters was experimentally investigated by comparing the discharge characteristics, thrust performance, beam characteristics, and spectral characteristics of thrusters with two different anode diameters of 15 and 30 mm. The 30 mm thruster has thrust of 78–235 mN, specific impulse of 566–1071 s, and anode efficiency of 11.8–23.4% at 78–235 W anode power. Compared with the 30 mm thruster, the anode power and thrust of the 15 mm thruster were decreased by approximately half. Plume diagnostic results show that the 15 mm thruster had a higher current utilization, higher ion peak energy and more active ionization due to better electron confinement. However, the propellant utilization of the 15 mm thruster was lower because of the shortened ionization region length.