Abstract
Data from exercise tests, echocardiograms, and lung perfusion scans were analyzed to determine whether the excessive minute ventilation (VE) often encountered among patients with tetralogy of Fallot is due to ventilation-perfusion mismatch secondary to branch pulmonary artery stenoses. Patients with branch PA stenoses had lower peak oxygen consumptions and higher VE during exercise than did patients without stenoses, and a strong correlation existed between the degree of pulmonary blood flow maldistribution on lung perfusion scan and the amount of excessive VE during exercise.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have