Abstract

To compare prospectively the effect of different insertion torques (ITs) on marginal bone stability and study the effect of soft-tissue and buccal bone thickness as confounding factors while using a 3-dimensional radiographic evaluation. Thirty-nine implants were placed in 22 patients. IT, soft-tissue thickness, and buccal bone thickness were recorded at implant placement. Marginal bone loss was evaluated on individualized periapical radiographs and cone-beam computed tomography at 1 year after loading. Three groups of implants emerged based on their IT: group I (<30 Ncm), group II (between 30-45 Ncm), and group III (>45 Ncm). Soft-tissue thickness was ≤2 mm in 10 implants (25.6% thin biotype) and more than 2 mm in 29 implants (74.4% thick biotype). No significant difference in marginal bone loss was found for different IT and different soft-tissue thickness. A significant correlation was found between initial buccal bone thickness (≥2 mm or <2 mm) and marginal bone loss at 1 year. IT and mucosal tissue thickness did not influence marginal bone loss. Buccal bone thickness of ≥2 mm was associated with a minimal marginal bone remodeling.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.