Abstract

The study explores the feasibility of a new all-steel buckling restrained brace (BRB) with the double pre-tensioning system as an alternative to conventional concentrically braced frames by using finite element method (ABAQUS program), And to verify modeling, use U-V1 specimen results and compare them with test results. The restraining element in an all-steel BRB is built from a rectangular plate with a double cross arm and cables, making it easy to fabricate, inspect, and replace after a severe earthquake. Numerical analyses were conducted on four groups: first group of specimens using dynamic loading to achieve the minimum thickness for stable hysteretic behavior and high efficiency for BRB, and three groups of specimens using monotonic loading to achieve the best pre-tensioning forces value in steel 37, 44 and 52 for greater efficient use of all steel BRB. The results showed a 66% improvement in bearing capacity, with the external restraining case thickness reduced to 20 mm, making it lightweight, economical, and easy to maintain. The specimens with a pre-tensioning force of 70 kN, 50 kN and 40 kN providing a 31%, 51% and 73.2 % for steel 37, 44 and 52 respectively over than the design specimen without pre-tensioning system.