Abstract

Catheter-associated urinary tract infection (CAUTI) is an important cause of prolonged hospital stay, which increases economic and medical burden for patients and hospitals, and it is a key focus of hospital infection prevention and control. However, there are currently few studies that convert evidence-based scientific evidence on CAUTI prevention and control into clinical applications and evaluation on its practical effects in combination with standardized infection ratio (SIR), the critical indicator of infection prevention and control. This study aims to establish a precision management plan for reducing the incidence of CAUTI, driven by the findings of a comprehensive evidence summary, to apply this plan across all the nursing units within the entire hospital, followed by a comparative analysis of CAUTI incidence, SIR, the average duration of indwelling urinary catheter for each patient, and the compliance rate on hand hygiene protocols for medical staff before and after the implementation of the precision management plan. Based on a comprehensive review of the best evidence for preventing CAUTI, a precision management plan was meticulously developed through panel discussions and 2 rounds of expert consultations using Delphi technique. Subsequently, a historical control study was conducted to evaluate the plan's effectiveness. A total of 17 658 patients with indwelling urinary catheter in inpatient departments from January to December 2021 comprised the control group. These patients received standard nursing measures for CAUTI. Another 18 753 patients with indwelling urinary catheters in the inpatient departments from January to December 2022 comprised the intervention group, underwent the precision management scheme based on the best available evidence, to enhance CAUTI prevention. The incidence and SIR of CAUTI, the average duration of indwelling urinary catheter for each patient, and the compliance rate on hand hygiene protocols for medical staff were compared between the 2 groups. Compared with the control group, the incidence of CAUTI in the intervention group was significantly decreased (0.48‰ vs 1.12‰, χ2=20.814, P<0.001), SIR was decreased in the intervention group (0.55 vs 1.37); the average duration of indwelling urinary catheter for each patient was significantly decreased [(4.33±1.55) d vs (4.43±1.79) d, t=11.941, P<0.001]. The ratio of compliance rate of medical staff with strict hand hygiene protocols higher than 95% in the intervention group was significantly higher than that in the control group (93.3% vs 83.3%, χ2=5.822, P=0.016). The implementation of the precision management plan for reducing CAUTI based on a summary of the best available evidence on CAUTI prevention and control in patients with indwelling urinary catheters has found to be effective. This approach significantly reduces the incidence of CAUTI, reduces the average duration of indwelling urinary catheter, and enhances hand hygiene compliance among medical staff. It provides a scientific and efficient strategy for preventing and controlling CAUTI in the hospital, ultimately saving patients from unnecessary medical expense.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call