Abstract

This research mainly describes the generation and diagnosis of plasma using a wire-plate discharge device driven by different power supplies, aimed at investigating the effect of driving source parameters on micro-discharge induced by a corona. The influence of parameters such as waveform, duty ratio and bias voltage on discharge characteristics was explored preliminarily. Experiment results show that the determination of volt-ampere characteristics under different driving source waveforms indicates that the application of square and pulse waveforms shows great advantages over that of sawtooth and sinusoidal waveforms. Similarly, the photo-thermal effects of the system were investigated by comparing the high-voltage electrode temperature and relative emission intensity of N2 (C3Пu → B3Пg, 0–0, 337 nm), where square and pulse waveforms also achieved better performance. But the pulse waveform had a slight advantage over the square waveform in terms of energy conversion. Further, investigations of the duty ratio and bias voltage applied on the pulse waveform were conducted, and the results indicate that the duty ratio could effectively improve the discharge power and thermal effect to a certain extent; however, the application of bias voltage on the pulse signal had little influence on the discharge power and thermal effect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call