Abstract

Distribution of the contamination on insulators is often irregular, which threatens the reliability of outdoor insulation. This work aimed to study the influence of pollution distribution, humidity and dry band location with various scenarioes on flashover characteristic of insulators. Flashover tests of cup-pin glass polluted insulators were conducted. Findings indicated the difference between the flashover performances of insulators under different pollution distribution. The flashover characteristics like voltage and current are greatly affected by salt deposit density (SDD), distribution modes, and distribution area. The relation between U50 and SDD has positive power function with more contrast in distribution. Insulators with more regular distribution have lowest flashover voltage and highest critical leakage current. Different distribution modes lead to the change of the conductivity of the contamination layer and the uneven distribution of the current density, which is the main cause that the characteristics of pollution flashover are directly related to the pollution modes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.