Abstract

Treated wooden utility poles, from trees such as eucalypts, are the most commonly used for telephone and electricity transmission lines in Uganda. In the last decade, however, frequent failure of wooden poles in service has been reported, likely due to the preservative chemical, wood used or the treatment process. The objective of this study was to assess the creosote preservative penetration and retention in eucalypt wood. A total of 126 Eucalyptus grandis poles i.e. 42 poles for each size category, with an average moisture content of below fibre saturation point (28%) were treated in different charges depending on their size. In length, poles used were 9, 11 and 14m. Every charge consisted of poles within the same size category. The Full Cell pressure method was used to treat the different charges with creosote preservative. For all the charges the same treatment schedule was maintained. Creosote penetration was highest in 14m poles (20.5mm) and lowest in 9m poles (18.4mm), Creosote retention was also highest in 14m poles (193kgm-3), but lowest in 11m poles (162kgm-3). Irrespective of differences in level of penetration and retention among the various pole sizes, all the poles acquired more than the required standard minimum level of penetration and retention i.e. 15mm and 115kgm-3 respectively. However, for all the pole sizes, creosote penetration was less than the sapwood depth. The current treatment schedule seems better suited for the larger poles of 14m than the 9 and 11m. For better treatment, it is recommended that smaller poles i.e. 9m and 11m should be treated for a longer period than 14m poles since they tend to have lager sapwood. The minimum basis of 15mm penetration should be increased to at least cover the entire pole sapwood depth.

Highlights

  • Preservative treatment greatly increases the service life of wood structures (Lebow et al 2004), reducing replacement costs and allowing more efficient use of forest resources

  • A total of 126 poles i.e. 42 poles for each size; 9, 11, and 14m having an average moisture content below 28% were treated in different charges depending on their lengths, using creosote preservative

  • Creosote penetration was highest in 14m and lowest in 9m (Table 2) while retention was highest in size 14m and lowest in 11m poles (Table 2)

Read more

Summary

Introduction

Preservative treatment greatly increases the service life of wood structures (Lebow et al 2004), reducing replacement costs and allowing more efficient use of forest resources. The treatment methods used involve pressure/vacuum processes to ensure good preservative penetration and retention. Of recent, frequent premature failures of treated poles in service have been reported in different parts of the country leading to financial losses and risking lives in the case of electric transmission lines. This has raised questions regarding the wood material used, suitability of the preservative chemicals, and the methods of treatment

Objectives
Methods
Results
Discussion
Conclusion
Full Text