Abstract

This paper presents a comprehensive study of the effect of polarization voltage on the measured mechanical Quality (Q) factor of a multiple-beam tuning-fork gyroscope. An experimental study is conducted to examine the effect of different variables in the experiment on the measured Q of the gyroscope. The experimental data show that the Q drops significantly with polarization voltage, while independent of ac drive voltage and feedback resistance. To identify the reason behind the Q drop with polarization voltage, the two loss mechanisms, thermoelastic damping and anchor loss, in the device are analyzed. Using a numerical model of thermoelastic damping capable of taking prestress into account, polarization voltage is found to have a negligible effect on the Q of the gyroscope. Due to the asymmetry of the fabricated devices resulting from fabrication variations, anchor loss is identified as the cause of the Q drop with polarization voltage. Based on the experimental data and related elastic wave theories, an analytical model of anchor loss is proposed to take polarization voltage into account.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.