Abstract Objective This investigation compared the biomechanical properties of a 2.0 mm locking compression notched head T-plate (NHTP) and 2.0 mm straight locking compression plate (LCP), in a compressed, short, juxta-articular fragment fracture model. Methods Two different screw configurations were compared for the NHTP and LCP, modelling short (configuration 1) and long working length (configuration 2). Constructs were tested in compression, perpendicular and tension four-point bending and torsion. Plate surface strain was measured at 12 regions of interest using three-dimensional digital image correlation. Stiffness and strain were compared. Results The LCP was stiffer than the NHTP in all three planes of bending (p < 0.05). The NHTP was stiffer than the LCP in torsion (p < 0.05). The NHTP had greater strain than the LCP during compression bending and torsion (p < 0.0005). The short working length NHTP was stiffer in all three planes of bending and in torsion (p < 0.05) than the longer working length. The short working length LCP was stiffer in compression bending and in torsion (p < 0.05) than the longer working length. The long working length showed greater strain than the short working length at multiple regions of interest. Conclusion In this experimental model of a compressed transverse fracture with a juxta-articular 9 mm fragment, a 2.0 mm LCP with two hybrid screws in the short fragment was stiffer than a 2.0 mm NHTP with three locking screws in the short fragment in three planes of bending but not torsion. Extending the working length of each construct reduced construct stiffness and increased plate strain.

Highlights

  • Fractures with a very short proximal or distal juxta-articular fragment create particular biomechanical challenges, complicating implant selection and placement

  • The locking compression plate (LCP) was stiffer than the notched head locking compression plate T-plate (NHTP) in all three planes of bending (p < 0.05)

  • The NHTP was stiffer than the LCP in torsion (p < 0.05)

Read more

Summary

Introduction

Fractures with a very short proximal or distal juxta-articular fragment create particular biomechanical challenges, complicating implant selection and placement. Distal radial fractures in toy and miniature breeds are a common example of this, with the majority of these fractures reported to involve the distal third of the radius, resulting in a very short distal fragment.[1,2] Plate fixation has been reported to have good overall success in these cases.[3]. A recent clinical report described use of either a 2.0 mm notched head locking compression plate T-plate (NHTP) (LCP, Synthes GmbH, Oberdorf, Switzerland) or a 2.0 mm straight locking compression plate (LCP) (Synthes GmbH, Oberdorf, Switzerland) for distal antebrachial fractures in toy and miniature breed dogs weighing less than 6 kg.[1] Differences in design include differing plate geometry and dimensions, received July 27, 2020 accepted August 10, 2020.

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.