Abstract
AbstractHigh‐density polyethylene films 50 μm thick were exposed to the downstream plasma flow of RF glow discharges in argon, hydrogen, or oxygen. It was found that many transvinylene and unreacted radicals remain after the argon or hydrogen plasma treatment, and that carbonyl groups are formed in the oxygen plasma treatment.The conduction current was smaller in the hydrogen‐plasma treated samples and the samples exposed to oxygen or ozone after hydrogen‐plasma treatment than in the untreated samples. Thermal pulse current measurements indicate that the treated surface layer traps electrons or holes and reduces the field strength at the electrode surface, thus suppressing further injection of electrons or holes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.