Abstract

ANSYS was used to establish the calculation model of the temperature field for 9% Cr heat-resistant steel pipes in local post-weld heat treatment (PWHT). And the computation model has been validated experimentally. Based on the numerical model, the temperature field distribution was simulated for different pipe lengths in local PWHT, and effects of pipe length on the temperature distribution of heat treatment was further studied. Results show that increase of pipe length has little influence on equivalent temperature measurement point, soak band (SB) width of outer wall and axial temperature gradient, while it causes temperature difference between outer and inner wall to increase and soak band width to reduce significantly in inner wall. And when pipe length increases to a certain extent, the temperature field tends to be stable gradually.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.