Abstract

A new corrosion control system which is biological cathodic protection (CP) system was developed using the concept of microbial fuel cells (MFCs). Microorganisms available in domestic wastewater was utilised to generate electrons and supplied to the carbon steel pipe, and as consequence, protect the pipe from corrosion. There are various factors affect the performance of the system including the pH at the anode and cathode chamber. This study aims to analyse the optimum pH at anode and cathode. In this study, wastewater was used as the electrolyte and graphite rod as the electrode in the anode compartment while cathode compartment was filled with sand and carbon steel pipe acts as the cathode. Both compartments were connected by a plastic tubing and separated by the membrane. It was found that optimum pH at anolyte and catholyte were 8 and 6. The CP potential versus copper sulfate electrode (CSE) was -752 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe versus CSE was -560 mV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.