Abstract

This research was conducted to calculate the mass transfer coefficient value for ozonation reaction of κ-carrageenan solution in the bubble column reactor. Ozone gas was produced using ozone generator type corona discharge. In this study, operating conditions were regulated at ozone gas flow rate 2- 5 L min-1, pH 4-10, and temperature 29 ± 1 oC. Samples were tested every 5 minutes to determine the dissolved ozone concentration. The results showed that dissolved ozone concentrations increased with increasing ozonation time and ozone gas flow rate. However, a very high gas flow rate can increase turbulence so that the mass transfer coefficient (kLa) value decreased. In alkaline conditions, the formation of free radicals (HO*) increases so that the amount of dissolved ozone decreases. The kLa value of ozone gas in κ-carrageenan solution is slightly lower than the kLa value of the ozone gas in the water. The results of this study indicate that (kLa) ozone gas in water is 0.131 / minute while the value (kLa) in κ-carrageenan solution is 0.128 / minute.Keywords: ozone; mass transfer; pH; flowrate

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.