Abstract
Twenty-one patients with moderate to severe mitral stenosis were treated with percutaneous balloon mitral valvuloplasty (PBMV) using Inoue mitral double-lumen balloon catheters. Creatinine phosphokinase MB isoenzyme (CPK-MB) levels were measured at baseline, 5 min, 6 h, and 18 h post dilatation. Haemodynamic indexes, 12-lead ECGs, and 2-dimensional echocardiograms were performed to evaluate systolic function postprocedure. CPK-MB levels were modestly increased at 5 min and at 6 h postprocedure compared with the baseline level (p < 0.001) but were still within the normal reference range, except for one patient who had a level at 5 min minimally above the upper limit of normal. CPK-MB levels were not significantly increased at 18 h after the procedure. No significant changes in ejection fractions, 12-lead ECGs, and regional wall motion occurred in any of the patients studied. In conclusion, PBMV causes modest early elevation of CPK-MB. This elevation is not associated with changes in LV systolic function and does not interfere with the diagnosis of acute myocardial infarction using the enzyme elevation criteria.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.