Abstract

Background and ObjectiveDegenerative diseases of the spine have a negative impact on the quality of life of patients. This study presents the results of numerical modelling of the mechanical behaviour of the lumbar spine with patient-specific conditions at physiological loads. This paper aims to numerically study the influence of degenerative changes in the spine and the presence of an endoprosthesis on the creation of conditions for tissue regeneration. MethodsA numerical model of the mechanical behaviour of lumbar spine at healthy and after total disc replacement under low-energy impacts equivalent to physiological loads is presented. The model is based on the movable cellular automaton method (discrete elements), where the mechanical behaviour of bone tissue is described using the Biot poroelasticity accounting for the presence and transfer of interstitial biological fluid. The nutritional pathways of the intervertebral disc in cases of healthy and osteoporotic bone tissues were predicted based on the analysis of the simulation results according to the mechanobiological principles. ResultsSimulation of total disc replacement showed that osseointegration of the artificial disc plates occurs only in healthy bone tissue. With total disc replacement in a patient with osteoporosis, there is an area of increased risk of bone resorption in the near-contact area, approximately 1 mm wide, around the fixators. Dynamic loads may improve the osseointegration of the implant in pathological conditions of the bone tissue. ConclusionsThe results obtained in the case of healthy spine and osteoporotic bone tissues correspond to the experimental data on biomechanics and possible methods of IVD regeneration from the position of mechanobiological principles. The results obtained with an artificial disc (with keel-type fixation) showed that the use of this type of endoprosthesis in healthy bone tissues allows to reproduce the function of the natural intervertebral disc and does not contribute to the development of neoplastic processes. In the case of an artificial disc with osteoporosis of bone tissues, there is a zone with increased risk of tissue resorption and development of neoplastic processes in the area near the contact of the implant attachment. This circumstance can be compensated by increasing the loading level.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call