Abstract
The effect of particle size, filler loadings and x-ray tube voltage on the x-ray transmission in WO3-epoxy composites has been investigated using the mammography unit and a general radiography unit. Results indicate that nano-sized WO3 has a better ability to attenuate the x-ray beam generated by lower tube voltages (25–35kV) when compared to micro-sized WO3 of the same filler loading. However, the effect of particle size on x-ray transmission was negligible at the higher x-ray tube voltages (40–120kV).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.