Abstract

Buildings are often located near ambient air pollution sources such as wildfire or heavy traffic areas. While windows in buildings are intermittently open for free cooling or natural ventilation, increased leakage area can lead to elevated human exposure to air pollutants of outdoor origin. The objective of this study is to investigate the effectiveness of paper filter windows in reducing exposure to outdoor air pollution and improving indoor air quality. The physical properties of paper windows as filtration media were experimentally determined, based on which multi-zone indoor air quality and ventilation analysis (CONTAM) simulations were performed for a full-scale building. The results show that the outdoor-indoor air exchange rate of a building can increase about 100% when conventional windows are replaced with paper filter windows. Even with the increased air exchange rate, the infiltration of outdoor particles into the building was reduced about 57–77% for the particle size range of 7–300 nm. These findings imply that paper windows have potential benefits for controlling both outdoor originated pollutants and indoor-generated pollutants with minimal energy inputs, especially in cities and communities impacted by urban air pollution and wildfires.