Abstract

BackgroundThe first oral glucagon-like peptide-1 receptor agonist (GLP-1RA) comprises semaglutide co-formulated with the absorption enhancer, sodium N-(8-[2-hydroxybenzoyl] amino) caprylate (SNAC). Oral semaglutide may alter the pharmacokinetics of co-administered drugs via effects of semaglutide or SNAC. Two separate one-sequence crossover trials investigated the effects of oral semaglutide and SNAC on the pharmacokinetics of ethinylestradiol, levonorgestrel, furosemide and rosuvastatin.MethodsHealthy, postmenopausal women (n = 25) received once-daily combined ethinylestradiol and levonorgestrel (Trial 1) and healthy male and female subjects (n = 41) received single doses of furosemide and rosuvastatin (Trial 2), either alone, with SNAC alone or with oral semaglutide. Lack of drug–drug interaction was concluded if 90% confidence intervals (CIs) for the ratio of area under the plasma concentration–time curve (AUC) or maximum concentration (Cmax), with/without oral semaglutide, were within a pre-specified interval (0.80–1.25).ResultsThe AUC values of ethinylestradiol and levonorgestrel were not affected by oral semaglutide co-administration (estimated ratios [90% CI] 1.06 [1.01–1.10] and 1.06 [0.97–1.17], respectively); Cmax was not affected. The no-effect criterion was not met for furosemide or rosuvastatin for the AUC (1.28 [1.16–1.42] and 1.41 [1.24–1.60], respectively) or Cmax. SNAC alone did not affect the AUC or Cmax of ethinylestradiol, levonorgestrel or rosuvastatin; the Cmax of furosemide was slightly decreased. Adverse events were similar to those previously observed for GLP-1RAs (both trials).ConclusionCo-administration with oral semaglutide did not affect the pharmacokinetics of ethinylestradiol or levonorgestrel. There was a small increase in exposure of furosemide and rosuvastatin; however, these increases are not expected to be of clinical relevance.Clinical Trial Registration NumbersNCT02845219 and NCT03010475.Supplementary InformationThe online version contains supplementary material available at (10.1007/s40262-020-00976-x).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.