Abstract

A study of the impact of service factors on Ti-6Al-4V alloy hydrogenation at temperatures close to climatic is performed on the example of a failed hydrogen compressor. It is established that under high gas pressure conditions and possible metal heating hydrogen saturation of Ti-6Al-4V alloy can reach significant values that surpass those acceptable by one to two orders of magnitude. Hydride phases are determined in the alloy by X-ray phase analysis. Temperature programmed desorption provides identification of phase transitions occurring during hydrogen evolution from the metal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.