Abstract

This study addresses seismic retrofit of reinforced concrete flat slab–column connections against punching shear failure. The tested slabs are retrofitted using shear bolts. These bolts were developed for installation in existing slabs by drilling holes around columns or concentrated load application points and then tightening against the slab surfaces. Slabs with and without openings are investigated. The effect of the pattern of shear reinforcing elements around the column area, namely orthogonal and radial is also investigated. This paper describes tests on six flat slab–column specimens; three with two openings at the column and three without openings. Among each of the three specimens in a group, one has no shear reinforcement; one is retrofitted in the orthogonal pattern; and one in the radial pattern. The test results, comparisons of the behavior of the specimens, and comparisons with the current code formulas are presented and discussed. The results indicate that shear bolts increase lateral drift capacity and ductility of the slab–column connections.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.