Abstract

Wire wound H-coils used for rotational measurements are not completely immune to off-axis components of magnetic field strength H. As a result, such components are capable of introducing the significant difference between the rotational power loss measured in the clockwise (CW) or anticlockwise (ACW) direction of rotation. These measurement errors do not influence the average value, and they are distinctly different from the errors caused by the angular misalignment of the sensors in the field metric method. As demonstrated in this study even ideal angular positioning of the H-coils could still produce CW-ACW differences at the level of ±15% at lower flux density and ±30% close to saturation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.