Abstract

The special clamp for fatigue of shaft under bending, torsion, and bending-torsion that used on the fatigue machine is designed and manufactured. The low-cycle fatigue experiments of shaft with annular notch under cantilever bending have been made. Through experiments and analysis, the effects of tip radius, depth and open angle of notch on low cycle fatigue life of shaft with annular notch under cantilever bending are obtained. The method and results will play an important role on the fatigue life prediction and anti-fatigue design.