Abstract

IntroductionThe aim of this study was to evaluate the effect of needle type and insertion depth, apical preparation size, and root canal curvature on irrigant extrusion by using a recently introduced method. MethodsSixteen human teeth with a straight root canal (group A) and 16 with a moderately curved root canal (group B) were sequentially prepared to sizes 25 or 35, .06 taper and mounted on a plastic vial filled with distilled water to simulate a periapical lesion. The vial was either closed or open to the environment. A point-conductivity probe was used to determine the volume of extruded irrigant into the vial. NaOCl was delivered by an open-ended or a closed-ended needle at 1, 3, or 5 mm short of working length. Results were analyzed by two 4-way mixed-design analyses of variance. The level of significance was set to P < .05. ResultsThe open-ended needle extruded significantly more irrigant than the closed-ended. Irrigant extrusion decreased as needles moved away from working length or when the apical size was increased. Needle wedging increased extrusion, especially when an open-ended needle was used. Root canal curvature did not have a statistically significant effect on irrigant extrusion. ConclusionsNeedle type, needle insertion depth, and apical preparation size had a significant effect on irrigant extrusion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.