Abstract

Objectives To investigate the influence of mouth-motion fatigue on marginal-accuracy of partial-coverage-restorations-(PCRs) of various dental materials. Methods Eighty molars were prepared equally and divided into five groups ( n = 16). PCRs were fabricated of following dental materials: Group-GO = Gold-Pontor-MPF ‡, Group-TA = Targis*, Group-EX = IPS-e.max-Press*, Group-EM = IPS-Empress*, Group-PC = ProCAD*/Cerec 3 † ( ‡Metalor/*Ivoclar-Vivadent/ †Sirona-Dental-System). Gold-PCRs were cemented conventionally. Residual 64 PCRs were adhesively luted and subjected to masticatory loading (1.2 million-cycles, 1.6 Hz, 49 N) and thermal cycling (5 °C/55 °C, 60 s, dwell-time, 5500cycles). Discrepancies in marginal-accuracy were examined on epoxy replicas (200× magnification). Statistical analysis was performed by unpaired and paired t-tests ( α = 0.05). Results After cementing, marginal-accuracy (geometrical mean)[95% confidence limits] was recorded: GO-47[43–51]μm, TA-42[38–45]μm, EX-60[52–67]μm, EM-52[45–60]μm and PC-75[59–94]μm. No significant differences were found between groups GO, TA and EM. Values of Group-EX were significantly higher compared to Group-TA ( p = 0.04). Group-PC demonstrated significantly decreased marginal-accuracy towards groups GO ( p = 0.03) and TA ( p = 0.02). Except for Group-GO ( p = 0.01), no significant changes in marginal-accuracy were observed after mouth-motion fatigue and thermal cycling (GO-42[38–45]μm, TA-42[38–47]μm, EX-56[49–65]μm, EM-54[46–64]μm and PC-71[59–84]μm). However, Group-GO and Group-EM showed significant deviations in marginal-accuracy after aging ( p = 0.04). Marginal discrepancies of groups EX and EM were similar ( p = 1.0). Values of Group-PC were significantly higher when compared to groups GO ( p = 0.01) and TA ( p = 0.02). Buccal–lingual marginal discrepancies were significantly higher than mesial–distal in all groups and stages. Significance Cast-gold-PCRs demonstrated superior marginal-accuracy, followed by indirect ceromer PCRs. All-ceramic PCRs showed in vitro clinical acceptable marginal widths, even though CAD/CAM fabrication slightly compromised marginal-accuracy. Since preparation margins were not exposed to occlusal loading directly, increased marginal discrepancies due to marginal chipping during mouth-motion fatigue were not experienced.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.