Abstract

In Japan, light water reactors are built on the seacoast because they use seawater as the final heatsink. Leakage of seawater from the condenser section of the reactor could lead to contamination of the reactor coolant, and stainless steels can be susceptible to crevice corrosion in chloride-contaminated water. Therefore, it is necessary to develop counter measures for suppressing the initiation of crevice corrosion and for repassivating the corroding crevice to maintain structural reliability. To accomplish this, first the effect of molybdate anion on suppressing the initiation of crevice corrosion on 316L stainless steel in chloride-contaminated water was evaluated by potentiostatic immersion tests. Next, the effect of molybdate anion addition on the repassivation of corroding crevices was also evaluated through potentiostatic immersion tests as a function of the concentration of chloride anion. Based on the results of these examinations, the beneficial effects of the presence of molybdate anion on the suppression of initiation and propagation of crevice corrosion were quantitatively evaluated in terms of critical potentials.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.