Abstract

When designing a control system for vibration suppression of flexible structures using modal control strategy, one must know the modal displacements and velocities of the controlled modes. If the vibration control forces are designed based on inaccurate modal states, the closed-loop performance of the vibration control system will be degraded depending on the extent of the modal filter errors. In this study, the effect of modal filter errors on the vibration control characteristics of flexible structures is analyzed for IMSC (Independent Modal Space Control). A Lyapunov asymptotic stability condition that depends on the magnitude of the modal filter errors is derived. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator techniques. The extent of the response deviation is found to be proportional to the magnitude of the modal filter errors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.