Abstract

The most commonly used formulations for dry powder inhalations are binary ordered mixes composed of micronized drugs and coarse carriers. An optimal dry powder aerosol formulation should possess an optimal inhalation property and a good flow property. These characteristics are especially important for a multidose dry powder inheler (DPI). In the present study, model powder blend were prepared consisting of synthesized sugar (different particle sized isomalt; IM-PF, IM-FS, IM-F) as a carrier and micronized salbutamol sulfate (SS). These ordered mixtures were aerosolized by the multidose JAGO DPI (SkyePharma AG) and in vitro deposition properties (fine particle fraction, FPF) were evaluated by a twin impinger (TI) at a flow rate of 60 l/min. The separation property between SS and carrier particles was investigated by the centrifuge method and air jet sieve (AJS) method. It was found that FPF decreased with increasing carrier particle size. However, a large carrier particle possesses a good flow property. Therefore, the effect of mixing of fine carrier particles (IM-PF) into the large carrier particles (IM-FS) on dry powder inhalation property was investigated. When the proportion of IM-PF (fine carrier) increase from 0% to 25% of the total carrier powder blend, the FPF also increases from 16.7% to 38.9%. It is concluded that the effect of mixing of fine carrier particles might be a suitable method for improving the dry powder inhalation properties.