Abstract

Experimental and simulation studies have been conducted about the effect of mist injection position on particle separation performance of cyclone scrubber. The typical particle trajectories for the normal type cyclone are calculated. The optimum mist injection position is determined based on the simulation of particle trajectories. Two types of cyclone scrubbers that have different mist injection position were tested in this research. It was found that the particle separation efficiency is strongly depended on the mist injection position. With the injection of mist, the 50% cut size is smaller than the case with the injection of air only. It was also found that increasing liquid to gas flow ratio enhances the separation efficiency. The experimental data agreed with the numerical simulation based on the direct flow calculation method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.