Abstract

This study evaluated the potential effects of denture base resin water storage time and an effective denture disinfection method (microwave irradiation at 650 W for 6 minutes) on the torsional bond strength between two hard chairside reline resins (GC Reline and New Truliner) and one heat-polymerizing denture base acrylic resin (Lucitone 199). Cylindrical (30 x 3.9 mm) denture base specimens (n= 160) were stored in water at 37 degrees C (2 or 30 days) before bonding. A section (3.0 mm) was removed from the center of the specimens, surfaces prepared, and the reline materials packed into the space. After polymerization, specimens were divided into four groups (n= 10): Group 1 (G1)--tests performed after bonding; Group 2 (G2)--specimens immersed in water (200 ml) and irradiated twice (650 W for 6 minutes); Group 3 (G3)--specimens irradiated daily until seven cycles of disinfection; Group 4 (G4)-specimens immersed in water (37 degrees C) for 7 days. Specimens were submitted to a torsional test (0.1 Nm/min), and the torsional strengths (MPa) and the mode of failure were recorded. Data from each reline material were analyzed by a two-way analysis of variance, followed by Neuman-Keuls test (p= 0.05). For both Lucitone 199 water storage periods, before bonding to GC Reline resin, the mean torsional strengths of G2 (2 days--138 MPa; 30 days--132 MPa), G3 (2 days--126 MPa; 30 days--130 MPa), and G4 (2 days--130 MPa; 30 days--137 MPa) were significantly higher (p < 0.05) than G1 (2 days--108 MPa; 30 days--115 MPa). Similar results were found for Lucitone 199 specimens bonded to New Truliner resin, with G1 specimens (2 days-73 MPa; 30 days--71 MPa) exhibiting significantly lower mean torsional bond strength (p < 0.05) than G2 (2 day--86 MPa; 30 days--90 MPa), G3 (2 days--82 MPa; 30 days--82 MPa), and G4 specimens (2 days--78 MPa; 30 days--79 MPa). The adhesion of both materials was not affected by water storage time of Lucitone 199 (p > 0.05). GC reline showed a mixed mode of failure (adhesive/cohesive) and New Truliner failed adhesively. Up to seven microwave disinfection cycles did not decrease the torsional bond strengths between the hard reline resins, GC Reline and New Truliner to the denture base resin Lucitone 199. The effect of additional disinfection cycles on reline material may be clinically significant and requires further study.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.